手动创建 raid

##删除raid
root@scaler:~# /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdDel -L2 -A0

##创建raid
root@scaler:~# /opt/MegaRAID/MegaCli/MegaCli64 CfgLDAdd -r5 [41:5,41:6,41:7,41:8,41:9,41:10,41:11,41:12,41:13,41:14] -strpsz128 -A0 

raid 卡日志,保存到文件

/opt/MegaRAID/MegaCli/MegaCli64 -AdpEventLog -GetEvents -f raid.envent.log -a0

新加入硬盘,重新插拔硬盘

清除foreign key 
/opt/MegaRAID/MegaCli/MegaCli64 -CfgForeign -Scan -aALL 
/opt/MegaRAID/MegaCli/MegaCli64 -CfgForeign -Clear -aALL

如何查看和清除 raid的 cache ##删除,重建raid时可能需要
/opt/MegaRAID/MegaCli/MegaCli64 -GetPreservedCacheList -aALL 
/opt/MegaRAID/MegaCli/MegaCli64 -DiscardPreservedCache -L7 -aall


/opt/MegaRAID/MegaCli/MegaCli64 -PDMakeGood -PhysDrv[8:1] -a0
/opt/MegaRAID/MegaCli/MegaCli64 -CfgForeign -import -a0

常用检查 磁盘erro

/opt/MegaRAID/MegaCli/MegaCli64 -pdlist -a0|grep -Ei "enc|Slot Number|Firmware stat|media error |other error"

raid一致性检查

禁用一直性 检查
/opt/MegaRAID/MegaCli/MegaCli64 -AdpCcSched -Dsbl -Aall
启用一致性检查,
/opt/MegaRAID/MegaCli/MegaCli64 -AdpCcSched -ModeConc -Aall
查看一直性检查 信息
/opt/MegaRAID/MegaCli/MegaCli64 -AdpCcSched -info -Aall

在pdlist 中可以看到 硬盘类型

Media Type: Hard Disk Device,,如果是固态盘,会显示 solid state device
PD Type: SAS,,这个应该可以判断是 sata盘 还是sas盘。。

flush raid cache

/opt/MegaRAID/MegaCli/MegaCli64 -AdpCacheFlush -Aall

闪烁硬盘

MegaCli -PdLocate -start -physdrv [E:S] -aALL

write back 只对写有用。
BBu状态 会影响到 write back 模式 是否开启。

/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -Aall
对某一个具体的 logic disk 查看 all 改成 对应0,1,

物理盘,逻辑盘一起看

megacli -LdPdInfo -aALL

关闭raid组的告警

-AdpSetProp AlarmDsbl -aALL

/opt/MegaRAID/MegaCli/MegaCli64 ldpdinfo -aall |egrep "Slot |Firmware"

/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aAll

检查BBBU 状态,期望 optima

root@host185:~# /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aAll |grep -Ei battery

检查cache policy
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -Aall
Current Cache Policy 期望Current Cache Policy No Write Cache if Bad BBU
Disk Cache Policy 期望 disable

/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aAll

设置cache

./MegaCli -LDSetProp NOCachedBadBBU -Lall -aALL
./MegaCli -LDSetProp CachedBadBBU -Lall -aALL

检查RAId 初始化进度

/opt/MegaRAID/MegaCli/MegaCli64 -ldinfo -lall -a0

raid 跟换硬盘后,判断状态

 1417  /opt/MegaRAID/MegaCli/MegaCli64 -ldinfo -lall -a0|less
 1418  /opt/MegaRAID/MegaCli/MegaCli64 -ldpdinfo -a0|less

查看每个物理硬盘状态

 1419  /opt/MegaRAID/MegaCli/MegaCli64 -pdlist -a0|egrep "Slot Number|Firmware stat"

write through 改成 write back

/opt/MegaRAID/MegaCli/MegaCli64 LDSetProp WB -Lall -Aall
##更改1个logic disk

 /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp WB -L3 -A0
 /opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp WB -L4 -A0

查看电池状态

/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL
-AdpBbuCmd -GetBbuCapacityInfo -A0

换硬盘 ,查看rebuild进度

/opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -showprog -physDrv [40:7] -a0

关闭 读的cache

/opt/MegaRAID/MegaCli/MegaCli64 LDSetProp Direct -Lall -Aall

关闭 disk cache

/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -DisDskCache -Lall -Aall


shengguo
8 声望4 粉丝